This is a website exclusively for professionals, if you are a private customer and you are interested in our products, do not hesitate to contact us and we will indicate your nearest distributor.

Innowater SMC10 salt chlorinator with pH and Redox

Ref. No.: SMC10PHRX

The Innowater SMC10 salt chlorinator with pH and Redox monitoring combines automatic chlorine production via salt electrolysis with control of the water’s chemical balance. It offers a nominal output of 10 g/h and is designed for small private swimming pools. It features an LCD display, a bipolar cell, programmable polarity reversal and a transparent housing that facilitates inspection of the unit. The model should be selected based on the pool’s volume, temperature and conditions of use.

Units per box: 1

Complete your order with Salt test strip test kit .

Product information

Innowater SMC10 salt-based chlorinator with pH and Redox control

The Innowater SMC10 is a domestic salt chlorinator designed to automatically produce the chlorine required for water disinfection from the salt dissolved in the swimming pool. This configuration incorporates pH and Redox control functions, allowing both the chemical balance of the water and the production of disinfectant to be managed via a single system.

Nominal output of 10 g/h

The SMC10 model has a rated output of 10 grams of chlorine per hour.

According to the manufacturer’s guidelines, it can be used in swimming pools of up to 30 m³ when the water temperature is below 25 °C and up to 20 m³ when it exceeds 25 °C.

These values must be adjusted according to sun exposure, temperature, the number of bathers, filtration time, the pool cover and the specific conditions of the installation.

Automatic pH control

pH control allows this parameter to be measured and the dosage required to keep it close to the set value to be managed.

A correctly regulated pH enhances the effectiveness of chlorine and helps to reduce problems such as cloudy water, limescale, skin irritation or a loss of disinfectant capacity.

The exact contents of the supply must be confirmed before placing the order, including the dosing pump, the probe and the installation fittings.

Redox control of chlorine production

Redox measurement — also known as ORP — enables the oxidising and disinfecting capacity of water to be estimated.

The Redox control limits or adjusts the chlorinator’s output based on the measured value, preventing the unit from operating continuously once the setpoint has been reached.

The result is a control system that is better suited to the pool’s actual requirements.

Protected electronics and LCD screen controls

The chlorinator is fitted with a high-performance, waterproof power supply and an electronic system protected against overloads.

The sealed housing, which has no forced ventilation, helps to protect the electronic components from the typical environment found in plant rooms.

The LCD screen and menu system allow you to view and configure the device’s main functions.

Bipolar cell designed for easy inspection

The bipolar cell incorporates a programmable polarity-switching system that helps to reduce the build-up of deposits on the electrodes.

The transparent vessel allows the condition of the cell to be checked visually and any dirt or deposits to be detected without first dismantling the entire assembly.

The waterproof connector makes it easy to connect and disconnect the cell during installation and maintenance.

Recommended applications

The Innowater SMC10 with pH and Redox is particularly suitable for:

  • Private swimming pools.
  • Small swimming pools.
  • New installations using salt electrolysis.
  • Refurbishment of existing treatment systems.
  • Swimming pools that require automatic pH control.
  • Facilities where production is to be adjusted using Redox.
  • Professionals seeking to combine disinfection and chemical control.

Installation recommendations

The cell must be installed in the return circuit to the swimming pool, after the filter and other equipment such as heat pumps or solar systems.

Where acid is dosed to regulate the pH, the injection point must be installed downstream of the cell vessel. Direct injection upstream of the cell may cause corrosion of the electrodes.

The chlorinator should only be powered when the filter pump is running and water is circulating.

The electrical and plumbing installations must be carried out or supervised by a qualified professional and must comply with the manufacturer’s instructions.

You may also be interested in

News

Featured articles to improve your pool or your customers' pool

How to choose a salt chlorinator based on the volume of your swimming pool in cubic metres

Which salt chlorinator do I need, based on the volume of my swimming pool in m³?

Cubic metres are the starting point, but they are not enough on their own. To choose the right salt chlorinator, you need to ….
Read more →

How to prime a swimming pool pump and remove air from the circuit

The pump starts up, the motor is running, but the water isn’t circulating properly. When looking through the cover of the ….
Read more →
A professional working out which heat pump a swimming pool needs

What sort of heat pump do I need for my swimming pool?

To work out what sort of heat pump a swimming pool needs, we need to know its volume in cubic metres, the temperature we want to achieve, the ...
Read more →
TRYPOOL
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.